Review



circular and rectangular glycotech parallel plate flow chambers  (GlycoTech Corporation)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    GlycoTech Corporation circular and rectangular glycotech parallel plate flow chambers
    Circular And Rectangular Glycotech Parallel Plate Flow Chambers, supplied by GlycoTech Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/circular+parallel-plate+flow+chamber/vacuum+parallel+plate+flow+chamber+glycotech+31+001/pm38972570-410-33-34
    Average 90 stars, based on 1 article reviews
    circular and rectangular glycotech parallel plate flow chambers - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Human Neutrophils Will Crawl Upstream on ICAM-1 If Mac-1 Is Blocked
    Article Snippet: To perfuse the HL-60 cells and PMNs across the HUVEC monolayer, we used a circular parallel-plate flow chamber (Glycotech) under vacuum, fitted with a rubber gasket to create a rectangular flow path (h = 127 μ m, w = 0.25 cm).

    Article Title: Let's Get Rolling: Precise Control of Microfluidic Assay Conditions to Recapitulate Selectin-Mediated Rolling Interactions of the Leukocyte Adhesion Cascade.
    Article Snippet: 70% ethanol (Sigma, cat. no. 459836) PBS (Cytiva HyClone, cat. no. SH30256.01) Polyacrylamide gels on 25-mm coverslips, coated with adhesion proteins (see Basic Protocol 2) RPMI 1640 medium (Fisher Scientific, cat. no. 11-875-093) Fetal bovine serum (FBS) (Cytiva, cat. no. SH30071.03) Penicillin-streptomycin solution (penstrep) (Cytiva, cat. no. SV30010) Inverted light microscope with 10× or 20× phase objective and camera (>30 fps) and environment chamber (Nikon or equivalent) Circular parallel-plate flow chamber (Glycotech, cat. no. 31-001) with tubing and gaskets 20-ml syringes (Fisherbrand, cat. no. 14-955-460) Kimwipes (Fisher Scientific, cat. no. 06-666) Syringe pump (Harvard Apparatus, cat. no. 70-4500) 8-ml round-bottom tubes (Fisher Scientific, cat. no. 14-959-38C) 1.5-ml microcentrifuge tubes (Eppendorf, cat. no. 0030123611) Fine point tweezers (Fisher Scientific, cat. no. 12-000-122) 35-mm tissue culture dish (Corning, cat. no. 430165) Parafilm (Fisher Scientific, cat. no. 13-374-16)

    Article Title: Adherence of platelets to in situ albumin-binding surfaces under flow conditions: role of surface-adsorbed albumin.
    Article Snippet: Surfaces that preferentially bind human serum albumin (HSA) were generated by grafting albumin-binding linear peptide (LP1) onto silicon surfaces.. The research aim was to evaluate the adsorption pattern of proteins and the adhesion of platelets from platelet-poor plasma and platelet-rich plasma, respectively, by albumin-binding surfaces under physiological shear rate (96 and 319 s−1) conditions.. Bound proteins were quantified using enzyme-linked immunosorbent assays (ELISAs) and two-dimensional gel electrophoresis.

    Article Title: Crk adaptor proteins mediate actin-dependent T cell migration and mechanosensing induced by the integrin LFA-1
    Article Snippet: After 3 additional washes in PBS, surfaces were mounted onto a circular parallel-plate flow chamber (GlycoTech).

    Article Title: Diacylglycerol kinase zeta negatively regulates CXCR4-stimulated T lymphocyte firm arrest to ICAM-1 under shear flow.
    Article Snippet: T lymphocyte arrest within microvasculature is an essential process in immune surveillance and the adaptive immune response.. Integrins and chemokines coordinately regulate when and where T cells stop under flow via chemokine-triggered inside-out activation of integrins.. Diacylglycerol kinases (DGKs) regulate the levels of diacylglycerol (DAG) which in turn determine the activation of guanine nucleotide exchange factors (GEFs) and Ras proximity 1 (Rap1) molecules crucial to the activation of integrin lymphocyte function-associated antigen 1 (LFA-1).

    Article Title: Migration against the direction of flow is LFA-1-dependent in human hematopoietic stem and progenitor cells
    Article Snippet: To perfuse the KG1a cells and HSPCs across the HUVEC monolayer, we used a circular parallel-plate flow chamber (Glycotech 31-001) under vacuum, fitted with a rubber gasket to create a rectangular flow path ( h =127μm, w =0.25 cm).

    In Situ:

    Article Title: An integrated assay to probe endothelial glycocalyx-blood cell interactions under flow in mechanically and biochemically well-defined environments.
    Article Snippet: .. Functionalisation of HA films in situ within parallel-plate flow chamber The circular parallel-plate flow chamber (GlycoTech, MD, USA) was fitted with inlet/outlet tubing (PTFE, with internal diameter 0.56 mm, Fisher Scientific) and a rubber gasket (spacer, with defined channel of dimensions: 0.250 × 2.5 × 20 mm (h × w × l)). ..



    Similar Products

    90
    GlycoTech Corporation circular and rectangular glycotech parallel plate flow chambers
    Circular And Rectangular Glycotech Parallel Plate Flow Chambers, supplied by GlycoTech Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/circular+parallel-plate+flow+chamber/vacuum+parallel+plate+flow+chamber+glycotech+31+001/pm38972570-410-33-34
    Average 90 stars, based on 1 article reviews
    circular and rectangular glycotech parallel plate flow chambers - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    GlycoTech Corporation circular parallel-plate flow chamber
    Circular Parallel Plate Flow Chamber, supplied by GlycoTech Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/circular+parallel-plate+flow+chamber/parallel+plate+flow+chamber/pm38578028-337-67-71
    Average 90 stars, based on 1 article reviews
    circular parallel-plate flow chamber - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    GlycoTech Corporation circular parallel plate flow chamber
    Circular Parallel Plate Flow Chamber, supplied by GlycoTech Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/circular+parallel-plate+flow+chamber/parallel+plate+flow+chamber/pm38578028-81-16-15
    Average 90 stars, based on 1 article reviews
    circular parallel plate flow chamber - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    GlycoTech Corporation parallel plate flow chamber circular flow chamber kit
    Parallel Plate Flow Chamber Circular Flow Chamber Kit, supplied by GlycoTech Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/circular+parallel-plate+flow+chamber/rectangular+parallel+plate+polycarbonate+flow+chambers/10__1161_slash_atvbaha__122__318085-125-15-20
    Average 90 stars, based on 1 article reviews
    parallel plate flow chamber circular flow chamber kit - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    GlycoTech Corporation 35mm circular plug parallel plate flow chamber
    35mm Circular Plug Parallel Plate Flow Chamber, supplied by GlycoTech Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/circular+parallel-plate+flow+chamber/35+mm+round+glass+no++1+coverslips/pm30509068-133-2-8
    Average 90 stars, based on 1 article reviews
    35mm circular plug parallel plate flow chamber - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results